Roll over image to zoom in
Dräger Interlock® 7500
$2,327.63
Units Sold: 0
- Alcohol ignition interlock device
- Tamper-proof & documents circumvention attempts
- Large colour display and simple menu navigation
- Can also be used at temperatures below 0 °C
- Measuring range: up to 3.0 mg/L
Application overview
- Prevents drink-driving
- Minimises alcohol-related accident risks
Dräger Interlock® 7500
Dräger Interlock® 7500 is an alcohol ignition interlock device which prevents a person under the influence of alcohol from starting the vehicle, efficiently minimising alcohol-related accident risks. It is protected against tampering and documents circumvention attempts in the integrated data memory. Another advantage of the alcohol ignition interlock device is that it can be used at temperatures below 0 °C. In addition to an easy-to-interpret measurement result, which is shown on the large colour display, simple menu navigation also ensures that the device is easy to use.
Product Details
- Dräger Interlock® 7500
- Alcohol ignition interlock device
- Consisting of a handset and a control unit
- Prevents drunk driving
- Quickly ready for use
- Minimises alcohol-related accident risks
- Protected against tampering
- Documents circumvention attempts in the integrated data memory
- Large colour display and simple menu navigation
- Intuitive and uncomplicated operation
- Coloured LEDs on the device enhance the ease of use
- Can be used at temperatures below 0 °C
- Compatible with hygienic disposable mouthpieces (biodegradable)
- Adjustable alcohol limit value
- Attractive and ergonomic design
- Data can only be read by authorised persons
Specifications
Measuring principle | Electrochemical Dräger Sensor |
Messbereich | Up to 3.0 mg/L |
Operating temperature | -40 to +85 °C |
Calibration interval | 12 months |
Dimensions (hand-held unit) | Approx. 138 x 61 x 36 mm (H x W x D) |
Dimensions (control unit) | Approx. 148 x 90 x 32 mm (H x W x D) |
Weight (hand-held unit) | Approx. 240 g |
Weight (control unit) | Approx. 240 g |
Power supply | 12-24 V |
Test result display | Test OK/Test not OK |
Breath test volume | 1.0 l |
Limit value (initial test) | 0.30 ‰ or 0.20 ‰ |
Restart period | 30 minutes |
Reviews
There are no reviews yet.